5/2 way Namur Pneuamtic Solenoid Valve 4M210-08 

Price: 3.5 USD 
Payment Terms: T/T,L/C,WU 
Place of Origin: Zhejiang, China (Mainland) 
inquire skype
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Means of Transport: Ocean,Air
Packing: Cartons/Pallets
Power: Solenoid
Pressure: Medium Pressure
Material: aluminum alloy
Media: Gas
Seals: NBR
Production Capacity: 10000Sets/month
Delivery Date: 15-30Days
Standard or Nonstandard: Standard
Structure: Control
Temperature of Media: Normal Temperature
Brand Name: SUPERMECH

*anti-explosion style;
*Internally piloted;
*Best price,high quality,steady performance.

Product name: 4M210-08 Series solenoid valve


Model

4M210- 06

4M220-06   

4M210-08

4M220-08

4M310-08

4M320-08

4M310-10

4M320-10

Media

Air

Action

Internally piloted

Type

5port 2 position

Orifice Size

14mm²(Cv=0.78)

16mm²(Cv=0.89)

25mm²(Cv=1.4)

30mm²(Cv=1.68)

Port Size

In=Exhaust=1/8"

In=1/4"  Exhaust=1/8"

In=Exhaust=1/4"

In=3/8"  Exhaust=1/4"

Lubrication

Not required

Pressure Range

1.5~8bar (21~114Psi)

Proof Pressure

12bar (170Psi)

Temperature Range

-5~60°C(21~140°F)

Voltage Range

-15%~+10%

Power Consumption

AC:3.5VA DC:2.5W

Insulation

F class

Protection

IP65 (DIN40050)

Weight

220g

320g

220g

320g

310g

400g

310g

400g

4M210-08


4M220-08


4M320-10




Solenoid Valve Installation Notes:

1 the installation should pay attention to the arrow on the valve body should be consistent with the medium flow. There can not be installed in direct dripping or splashing water. Solenoid valve should be installed vertically upward.

2 solenoid valve should ensure that the supply voltage is the rated voltage fluctuation range of 15% -10% of normal work.

3 Solenoid valve is installed, the pipeline must not have reverse pressure differential. And the required power for several times, so that proper temperature before officially put into use.

4 Solenoid valve piping should be thoroughly cleaned before installation. Pass into the media should be free of impurities. Valve pre-installed filters.

5 When the solenoid valve malfunction or cleaning, to ensure the system continues to run, you should install the bypass device.


Contacts:

NINGBO SUPERMECH PNEUMATIC HYDRAULIC CO.,LTD.

Sales: Tracy zhang

Skype: tracy.zhang5

Tel: +86-574-88867713

Fax: +86-574-88865713


Ms. Tracy Zhang
skype Ms. Tracy Zhang
Sales Administrator
Tel: 86-574-88867713
Fax: 86-574-88865713
Mobile: 135 0669 9035
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Related Products

Company Info

NINGBO SUPERMECH PNEUMATIC HYDRAULIC CO., LTD. [China (Mainland)]


Business Type:Manufacturer, Trading Company
City: Ningbo
Province/State: Zhejiang
Country/Region: China (Mainland)

Follow Us: Follow us on facebook

Tracy:   skype
Tracy Zhang:   qq

You May Like: